Modular Structures for Hazardous Locations, Modular Buildings, Portable Facilities, IN Speed Space - Modular Laboratory Structures
PRODUCTS Modular
Office Systems
Modular
Exterior Buildings
Plumbed Modular
Buildings
Modular Equipment
Enclosures
Modular Laboratory
Facilities
Modular Structures for
Hazardous Locations
Closeouts
MADE WITH PRIDE
IN THE USA Security to the U.S. Capitol building was greatly enhanced by this Speed Space washroom application during renovation
Guarantee
All Categories > Modular Office Systems > Plumbed Modular Buildings > Modular Exterior Buildings > Modular Equipment Enclosures > Modular Laboratory Structures > Modular Laboratory Structures  
    Printable Page     Email Email This Page     Save To Favorites Save To Favorites
Request Information

Modular Laboratory Structures



    Email Email This Page  
    Save To Favorites Save To Favorites
  


Speed Space offers many options for controlled environment applications. Microbial and fungal resistant wall panels are available in several options. Choose from epoxy coated aluminum, stainless steel, FRP or our special line of EnviroGuard TM and CleanCote R panels, both from Citadel Architectural Products. Our laboratories are available with all steel construction with no wood, thus eliminating any chance for mold growth.

Is environmental control and fire suppression a requirement for your laboratory? No worry, Speed Space can provide positive or negative pressure air handling systems with HEPA filtration, air curtains and wet or chemical sprinkler systems. Other options include Pass-Thru Air Lock Doors and Dust Containment Cabinets.

All electrical components are UL listed and wiring installations comply with the National Electric Code. Speed Space has over 3 decades of experience in fabricating portable facilities for animal housing labs, environmental rooms, clean rooms, and testing facilities.

Exterior siding of modular buildings can be constructed from galvanized 29-gauge steel. Our portable units can be disassembled and installed easily. Off-site manufacturing capability enables us to meet quick delivery schedules without disrupting your operations. Speed Space Modular Laboratory Structures can be stacked, disassembled, and extended to meet your changing workspace requirements.



Specifications · Standard Specifications · Durability and Weather Resistant Features

Specifications

Capabilities

Assembly
Delivery
Design and Engineer
Fabrication
Inspection
Installation

Applications

Animal Housing Labs
Clean Rooms
Environmental Rooms
Microbiology
Paint Mixing Rooms
Propane Plants
Testing Facilities

Modular Building Construction Materials

Aluminum
Steel
Wood

Wood Construction Materials

No.2 Grade Lumber
Pine or Fir
Spruce

Blast Overpressure

5 psi to 20 psi

Ceiling Height

7' to 10'

Standard Sizes

Length: 8' to 40'
Width: 8' to 12'

Maximum Modular Structure Size

40' x 40'

Modular Building Weight

1,200 lbs to 14,000 lbs

Standard Window Size

46" x 27"

Standard Door Size

36" x 80"

Testing Capabilities

FSP Test
V50 Test

Exterior Colors

Blue
Brown
Gray
Green
Red
Tan
White

Interior Wall Coverings

Beige
Calcutta Gray
Calcutta Tan

Standard Interior Floor Coverings

Ebony
Nutmeg
Sesame

Options

8' Ceiling Height and Higher
Additional Doors and Windows
Air Conditioning
Air Conditioning with Heater
Air Purifiers
Base Board Heat
Built-in Desks
Carpeting
Closets
Computer Wiring
Conduit (EMT) Wiring
Custom Roof Decking
Double Story
Exhaust Fans
Exterior Lighting
First Aid Equipment
In-Swing Doors
Lockers
More
No Floors
Partitions
Phone Jacks
Roof Overhangs
Security Windows and Doors
Sliding Windows vs. Picture
Sloped Roof
Smoke and Security Alarms
Special Floor Coverings
Special Windows
Sprinkler Systems
Tinted Windows
Transformers
Venetian Blinds
Wainscot
Washroom Facilities

Lead Time

3 to 4 weeks from the time of order.

Special Exterior Options

Exterior with Hip Roof
Wood Exterior with Wood Mansard
Steel Exterior with Slopped Roof
Exterior with Slopped Overhang Roof
Brick and Wood Exterior with Shingled Roof
Brick and Steel Exterior with Steel Mansard
Fiberglass Exterior with Radius Windows

Standards

  • Meet ballistic limits under MIL-STD-622F and MIL-P-46593A military standards.
  • Explosion Resistant Structures are available in Class Division 1 & 2, Groups A, B, C, D, E, F, and G.
  • Built to uniform building code specifications (Can build to specific code requirements upon request.)
  • All electrical components are UL listed & all wiring is per National Electric Code (latest edition).
  • Buildings comply with the applicable rules of the Indiana Fire Prevention and Building Safety Commission IC 22-15-4-2.

Industries Served

Automotive
Distribution Centers
Energy
Government Buildings
Manufacturing
Medical/Dental
Military
Mining
Oil Drilling
Others
Prisons/Correction Facilities
Private/Public Schools
Recycling
Restaurants
Steel Mills
Universities


Standard Specifications

Standard Features

1/8" Industrial Floor Tile
Complete Floor and Roof System
Diffused Lighting
Heavy Duty Vinyl Wall Covering
Interior Receptacles
More

Standard Options

Acoustical Accordion Doors
And More
Exhaust Fans
Heating and Air Conditioning
Hydraulic Door Closers
Sprinklers
Steel Doors

Perimeter Frame

Perimeter tubular 2" x 6" frame members (13 ga.) with structural steel “C” channel 2" x 8" set perpendicular to and inletted into side tubular bars. Channel is utilized as forkliftable slots for handling. All frame parts are coated with corrosive resistant (black) paint.

Metal Weather Shield

Galvanized steel construction. The shield covers the entire floor assembly and is located between frame and underside of floor joists.

Floor Joists

Joists are nominal 2 x 4 (1 1/2" x 3 1/2") spaced in a lateral configuration, 12" O.C. Lumber is #2 SPF or better.

Floor Insulation

Fiberglass batt-type insulation between floor joists is R-11 and entirely fills any and all voids.

Floor Decking

3/4" thick A.P.A rated plywood is fastened securely to floor joists with glue and ring shank nails (spaced approximately 4" O.C.). All seams are sanded smooth and filled as necessary.

Floor Covering

Vinyl composition floor tile 1/8" thick 12" x 12" squares are laid on the floor utilizing waterproof tile adhesive. Pattern full depth of tile.

Wall Studs

Studs are nominal 2 x 4 (1 1/2" x 3 1/2") space 16" O.C. Lumber is S.P.F. stud grade or better. Top plate is nominal 2 x 4 (1 1/2" x 3 1/2") fastened securely to studs. Bottom plate is nominal 2 x 4 (1 1/2" x 3 1/2") fastened securely to studs.

Wall Insulation

Fiberglass batt-type insulation between studs is R-11 and entirely fills any and all voids. Total R-value is R-14 with sheathing.

Interior Wall Covering

1/2" thick gypsum board with laminated vinyl covering is fastened to the inside of the studs with wide crown staples and gypsum adhesive; material has a class ‘A’ flame spread rating. 4" vinyl base cover.

Exterior Sheathing

Under steel siding structural sheathing is secured to entire exterior, per manufacturer’s recommendations. Sheathing is 1/8” structural thermo-ply.

Roof Framing

Rafters are nominal 2 x 4 (1 1/2" x 3 1/2") spaced in lateral configuration 16" O.C. Lumber is #2 SPF or better.

Interior Ceiling

Ceiling material is 1/2" gypsum with a white stucco pre-finish fastened securely to roof rafters with wide crown staples and screws. Material has a class ‘A’ flame spread rating.

Roof Insulation

Fiberglass batt-type insulation between roof rafters is R-11 and entirely fills any and all voids.

Exterior Roof Sheathing

The top side of the rafters has 7/16" sheathing fastened to roof rafters. Covered completely with a 4 mil. Polyvinyl vapor barrier.

Roof Covering

30 ga. Galvanized steel construction. Roof metal covers entire roof assembly.

Exterior Siding

Galvanized steel siding is 29 ga. Pre-finished (on both sides) commercial type with appropriate top and bottom trim fastener securely to studs. Seven standard colors are available. 40-year guarantee.

Windows

Windows are fixed glass (picture) type, double insulated glazing with vinyl extrusion around the perimeter. Windows are secured in place and sealed with a silicone-based sealant. Glazing is double 1/8". Sliding windows are optional.

Exterior Doors

Doors are a sandwich type construction with 0.019 aluminum on both faces and an interior core of foam and wood perimeter. A welded aluminum extrusion surrounds the assembly. This assembly is in turn pre-hung in an aluminum frame equipped with heavy-duty metal hinges. Door lite is fixed tempered glass single pane. Heavy-duty door closure included.

Full Depth Fork Pockets

All sizes 2 1/2" x 8" structural ‘C’ channel (3 1/2" x 7" opening).

Interior Light Fixtures

All light fixtures are 4'-0" (four foot) T8 twin tube with an acrylic wrap-around type diffuser cover.

Interior Ceiling Height

The dimension from the finished floor surface to the finished ceiling surface is 7'-0" (seven foot). 8' optional with 2 x 4 wall studs and R-11 insulation. Total R-value is R-14 with sheathing.

Electrical Service Panel

Pre-wire service entrance panel is equipped with a 60-amp main breaker, a 15-amp breaker (for lights), an additional 20-amp breaker (for receptacles), and any additional breakers necessary. Entrance conduit is through the exterior wall for ease of hook-up. All electric components UL listed and wired to National Electrical Code. Standard service is 240/120V, single-phase, 60 cycles.


Durability and Weather Resistant Features

Rain and Moisture Protection Options

All Speed Space buildings are designed for inside or outside use. Galvanized steel roof and under floor sheathing, double insulated glass windows, vapor barrier, moisture-proof sheathing assures excellent humidity control.

Wind, Cold, and Heat Insulation Options

Steel siding, structural thermal sheathing, full 3 1/2" insulation and thermal windows guarantee comfortable temperatures, even in the most severe weather.

Fire Resistant Options

Steel siding, roof and under floor sheathing, as well as gypsum interior, give Speed Space buildings a class ‘A’ flame spread rating on all surfaces. Sprinkler systems and totally non-combustible units available.

Noise Control Options

Structural sheathing, gypsum interior, and thermal windows create a decibel drop in the 25 to 30 decibel range, standard with windows and doors. For extreme conditions, optional sound control is available (triple-glazed windows, soundboard, and carpeting).

Damage Protection Options

Exterior steel siding with baked finish on both sides (40-year guarantee), structural sheathing, 1/8" industrial floor tile, heavy-duty vinyl interior walls, and a 4" rubber base molding all help to control accidental or deliberate damage. Doors are heavy-duty with kick plate, lite, and closure.


 MORE IMAGES 

· Modular Paint Mix Room

· Laboratory Eye Wash Sink

· Explosion Resistant Laboratory

· Chemical Resistant Laboratory

· Laboratory Testing Facility

· Exterior Laboratory Testing Facility


Request Information
Speed Space | Div. Commercial Structures Corp.